Tech Specs

Vitals360 Technical Specifications

Blood Pressure Monitor

  • Arm cuff fits 9” to 17” upper arm circumference
  • Mobile apps to track readings and email them to your physician.
  • Blood pressure monitor is clinically validated to accurately measure your systolic and diastolic blood pressure along with your heart rate. Easily perform a triple measurement average for the most precise feedback
  • Operating Conditions

  • 10~40C (50~104F) temperature,
  • 15~90% relative maximum humidity
  • Storage Conditions
  • -25~70C (-13~158F) temperature,
  • 10~95% relative maximum humidity
  • Measurement

    Oscillometric method with automatic inflation and controlled pressure release valve

    Measurement Range

    40~250 mmHg for blood pressure,

    40~200 beats/minute for pulse

    Measurement Accuracy

    Accuracy ±3mmHg or ±2% of readout value for blood pressure. ±5% of readout for pulse

    Measurement Resolution

    1mmHg for blood pressure. 1 beat/min for pulse.

Glucometer

No coding

Test results from capillary blood samples using the VoCare Inform II system show excellent correlation to reference samples, meeting the ISO accuracy acceptance criteria of ±15 mg/dL for results

Thermometer

Temperature range:

Min.: 32 °C (89.6 °F)

Max.: 43 °C (109.4 °F)

Accuracy = ±1F

Bluetooth

Bluetooth 4.2

IEEE 802.15.1

Wi-Fi

WiFi 802.11ac

The latest version of Wi-Fi, Wi-Fi CERTIFIED ac, offers healthcare facilities a significant performance leap, without sacrificing core competencies like interoperability, security and ease of use. Wi-Fi CERTIFIED devices are backward compatible, so newer devices will seamlessly interoperate with current devices. Wi-Fi CERTIFIED ac devices are also expected to include Wi-Fi CERTIFIED n, and dual-band networks will enable more capacity, higher throughput, better coverage and lower latency in healthcare environments. – See more at: http://www.wi-fi.org/discover-wi-fi/healthcare#sthash.tTCT9lUx.dpuf

Pulse & SpO2

SpO2: 1 – 100%

Range: 50-100

Accuracy: 2% from 75.0-100; 3% from 50-74.9

Pulse Rate: 25 – 240 (bpm)

ECG

2-lead ECG system for home, office, and travel use by the general public as instructed by a physician. It can also be used by physicians and other healthcare personnel responsible for recording patients’ cardiac rhythm. It records for periods of time chosen by the user, with the record then available for immediate review, subsequent analysis, printing, saving, and/or transmitting.

ECG waveforms

Detailed analysis report: In addition to displaying the ECG waveform, the Vitals360® device would displays various fundamental interpretations; including heart rate, cardiac rhythm and presence of premature contraction. These interpretations are based upon several predefined criterions. It is recommended that the user has complete understanding these criterions and their implications before making any clinical decisions.

Wireless Built-in Hub Specifications

Technology/Operating bands

Wireless protocol standards

GPS

LTE/EV-DO/HSPA+ Qualcomm® GobiTM 4G Module*

LTE: 1900 (Band 2) , 1700/2100 (Band 4), 850 (Band 5), 700 (Band 13), 700 (Band 17), 1900 (Band 25) MHz

HSPA+: 2100 (Band 1), 1900 (Band 2) , AWS 1700/2100 (Band 4), 850 (Band 5), 800 (Band 8) MHz E-GPRS: 1900 (Band 2), 1800 (Band 3) , 850 (Band 5) , 900 (Band 8) MHz

EV-DO: 800 (BC0), 1900 (BC1) MHz

3GPP Release 8 LTE Specification

WCDMA R99, 3GPP Release 5, 6 and 7 UMTS Specification EVDO Release 0 and Release A

Standalone GPS, A-GPS, GPS XTRA

1575.42 MHz (± 1.023 MHz), GLONASS 1596-1607MHz

LTE (Category 3): 100 Mbps (Download), 50Mbps (Upload) DC-HSPA+: 42 Mbps (Download), 5.76 Mbps (Upload) HSPA+: 21.6 Mbps (Download), 5.76 Mbps (Upload)

EDGE: 236.8 kbps (Download), 236.8 kbps (Upload) GPRS: 85.6 kbps(Download), 85.6 kbps (Upload)

LTE: +23 dBm

WCDMA: +23 dBm

GSM 850/900, GMSK: +32dBm

GSM 850/900, 8PSK: +27dBm DCS1800 / PCS 1900, GMSK: +29dBm DCS1800 / PCS 1900, 8PSK: +26dBm CDMA: +24dBm

LTE: 1,200 mA (peak); 900 mA (average) WCDMA: 1,100 mA (peak); 800 mA (average) EGPRS: 2,500 mA (peak); 700 mA (average)